Jets and water temperature

Water temperature control system


Air-Cooled Capacity1 (BTU/hr)

Water-Cooled Capacity1 (BTU/hr)

Compressor (Hp) Process Pump (Hp) Max Flow Rate Minimum Pressure Process Connection (FNPT) Condenser (FNPT) Water-Cooled Only Tank Size (Gallons) Dimensions2 (LxWxH) Approx. Shipping Weight2 (lbs.)
3, 540 3, 770 1/2*
Select a standard pump to meet process conditions or specify performance needs.
Hp GPM PSI
1/2 15
3/4 25 26
30 32
1-1/2 40
50
60 34
80 38
100
1" 1/2" 10 38"x25"x62" 450
15, 800 16, 700 1* 480
20, 700 21, 800 1 1/2* 20 50"x28"x63" 575
24, 400 25, 200 2** 600
32, 200 33, 300 3** 610
56, 100

58, 100

5** 1-1/2" 58"x37"x69" 715
89, 200 92, 000 7 1/2** 990

117, 900

121, 400 10** 1, 010
169, 800 175, 300 15** 68 80"x52"x65" 1, 850
226, 800 234, 800 20** 2, 050
271, 000 280, 000 25** 2" 100 142"x50"x80" 3, 900
350, 000 362, 000 30** 4, 150
441, 000 455, 000 20/20** 3" 200"x52"x85" 5, 300

Full Range chart is based on 1 single zone up to 24 kW heater with open circuit and fluid temperature range 20°F to 200°F (-7°C to 93°C).
1 Air-Cooled based on 50°F chilled water at 2.4 GPM/Ton and 90°F ambient air. Water-Cooled based on 50°F chilled water at 3 GPM/Ton and 85°F condensing water.

2 Water-Cooled condenser design may alter the dimensions and weights shown.

* Standard compressor on 0.5-1.5 Ton is reciprocating type. These models are not available in the scroll compressor.
** Standard scroll compressor type, 2-40 Ton.
Full Range designs are available in a variety of voltages, capacities, and process fluid temperatures ranging from -20°F to 300°F (-29°C to 149°C).
Oil Full Range designs are available in a variety of voltages, capacities, and process fluid temperatures ranging from 50°F to 650°F (10°C to 343°C).
Heating only and cooling only designs are also available.
For more information on any of the above or our line of Iceman Chillers, please contact Mokon.


Share this article





Related Posts



Latest Posts
Integrator company
Integrator company
Organizations qualified by PCI SSC as…
Role Based Access Control System
Role Based Access…
Role-based access control (RBAC) is a…
System Center 2012 R2 App controller
System Center…
Microsoft System Center App Controller…
Systems Galaxy Access Control
Systems Galaxy…
All 635 2 Reader Controller Packages…
DTMF remote control system
DTMF remote control…
The project works on the concept of DTMF…
Search
Featured posts
  • ON-OFF temperature control system
  • Fermenter temperature control system
  • Automatic temperature control Systems
  • Shower water temperature control system
  • Temperature control system block diagram
  • Temperature controlled system
  • Definition of inventory control system
  • Area Traffic Control system
  • Air Traffic Control Systems
Copyright © 2018 l www.oliver-control.com. All rights reserved.